ENERGIN® GEN+ units are generators sets with heat recovery from engine jacket water, lube oil and the first stage of mixture cooling. As an option they can be equipped with an exhaust heat exchanger cooling the exhaust to 250 °C.

ENERGIN® GEN+ units are generators sets with heat recovery from engine jacket water, lube oil and first stage mixture cooling. As an option they can be equipped with an exhaust heat exchanger cooling the exhaust to 250°C. For more efficient heat recovery please refer to our CHP units. ENERGIN® GEN+ units are prepared for power production in island or parallel mode with other generators and/or the utility.

The gas engines of the M-Series of R Schmitt Enertec are the base of the ENERGIN® GEN+ units in the range of 115-500kW electrical power.

The engines are specially designed and manufactured by us for the operation with the following fuels: natural gas, biogas, LPG, woodgas and other special gases. With the additionally sound enclosure, that is mounted on the common frame, the sound level can be reduced to less than 70 dB(A). GEN+ are easy to install and save on space because all major components are mounted on the common frame and are ready piped and cabled.

 

Natural gas, 400 V, 50 Hz

Model

Electric power

Electrical
Efficiency

Thermal power
without AWT* 

Overall Efficiency
without AWT*

Thermal Power
with AWT*

Overall Efficiency
with AWT*

M06 GEN+ G115

115 kW

36,5 %

125 kW

74,3 %

156 kW

83,9 %

M06 GEN+ G173

173 kW

35,8 %

173 kW

72,9 %

238 kW

83,0 %

M06 GEN+ G185

185 kW

36,5 %

169 kW

69,8 %

221 kW

80,1 %

M06 GEN+ G205

205 kW

37,5 %

142 kW

63,4 %

223 kW

78,2 %

M08 GEN+ G233

233 kW

37,7 %

199 kW

69,9 %

262 kW

80,1 %

M08 GEN+ G260

260 kW

37,8 %

176 kW

63,4 %

278 kW

78,2 %

M12 GEN+ G350

350 kW

38,1 %

295 kW

70,2 %

389 kW

80,4 %

M12 GEN+ G400

400 kW

38,5 %

261 kW

63,6 %

415 kW

78,5 %

M12 GEN+ G500

500 kW

39,5 %

282 kW

61,7 %

481 kW

77,5 %

* AWT - exhaust heat exchanger

 

Biogas, 400 V, 50 Hz

Model

Electric power

Electrical
Efficiency

Thermal power
without AWT*

Overall Efficiency
without AWT*

Thermal Power
with AWT*

Overall Efficiency
with AWT*

M06 GEN+ B115

115 kW

37,0 %

109 kW

72,0 %

142 kW

82,6 %

M06 GEN+ B173

173 kW

37,2 %

159 kW

71,4 %

209 kW

81,9 %

M06 GEN+ B205

205 kW

38,8 %

123 kW

62,1 %

204 kW

77,3 %

M08 GEN+ B233

233 kW

38,1 %

186 kW

68,5 %

252 kW

79,1 %

M08 GEN+ B260

260 kW

41,6 %

128 kW

62,1 %

224 kW

77,4 %

M12 GEN+ B350

350 kW

38,9 %

269 kW

68,8 %

366 kW

79,6 %

M12 GEN+ B400

400 kW

40,2 %

220 kW

62,3 %

374 kW

77,8 %

M12 GEN+ B500

500 kW

41,2 %

245 kW

61,3 %

438 kW

77,2 %

* AWT - exhaust heat exchanger

 

Woodgas, 400 V, 50 Hz

Model

Electric power

Electrical
Efficiency

Thermal power
without AWT*

Overall Efficiency
without AWT*

Thermal Power
with AWT*

Overall Efficiency
with AWT*

M08 GEN+ H166

166 kW

33,1 %

149 kW

62,2 %

217 kW

76,3 %

M12 GEN+ H250

250 kW

33,5 %

244 kW

66,2 %

321 kW

76,5 %

* AWT - exhaust heat exchanger

 

ENERGIN® M – Series gas engine specification

Bore

128 mm - in line engine

130 mm -V- engine

Stroke

155 mm - in line engine

142 mm - V- engine

Speed

1.500 rpm

Mean piston speed

7,75 m/s - in line engine

7,10 m/s - V- engine

Applicable gas typer

G = natural gas

B = biogas

H = woodgas and other low calorific gases

P = propane and other high calorific gases

Aspiration

N = natural

T = turbocharged

M = turbocharged with Miller Cycle

Mixture cooling

0 = none

I = internal

2 = double stage internal / external

Exhaust manifolds

W= watercooled

D = dry, unsulated

Engine types

 M06

M08

M12

No. of cylinders / config

6 in line

8 in V90°

12 in V90°

Displacement (ltr)

12.0

15,1

22,6

 

 

GEN+ Basic scope of supply                                                                                                                 

Four stroke gas engine coupled with double bearing alternator, mounted on common frame

Sound attenuating enclosure with air ventilation mounted on common frame with engine and generator

Heat recovery from engine jacket water, lube oil and 1st stage intercooler

Heat recovery from the 250 °C cooled exhaust gas

Remote radiator for 2nd stage of mixture cooling

Remote radiator for jacket water, lubrication oil and 1st stage intercooler

Remote radiator for jacket water, lubrication oil, 1st stage intercooler and exhaust heat

ENERSCREEN® control system with touchpanel for engine, generator and auxiliaries set mounted in switchboard. With synchronizing and generator protection functions

Generator circuit breaker set mounted in switchboard

Electric pre-lubrication pump with change over valve to use the pump for oil drainage and oil change

Set mounted lube oil make up tank with automatic level control on the engine oil pan

for automatic compensation of the oil consumption

Exhaust silencer single or double stage in loose supply

 as an option ● included